Clitheroe
Shap
Horwich, Bolton
Chorley
Horwich, Bolton
A quarry blast may last only a few seconds, but it still produces useful information about how vibration travels through the surrounding ground. Specialist monitoring equipment allows that brief event to be recorded and reviewed properly.
In this guide, we’ll look at how ground vibration is measured, what terms such as peak particle velocity mean and how monitoring results are interpreted.
A quarry blast is designed to break rock, but some of the energy also travels outwards through the surrounding ground as vibration waves. As these waves pass, particles within the rock and soil move very slightly before returning to their original position.
Ground vibration is separate from the sound of the blast and the air overpressure travelling through the atmosphere. It also isn’t the same as flyrock, which is the physical movement of stone from the blast area. Although these effects come from the same event, they’re measured and managed differently.
Our guide to the role of blasting in quarrying explains how blasting fits into the wider extraction process.
Quarry blast vibration is normally recorded using a specialist ground vibration monitor, also known as a blasting seismograph or vibrograph. It captures the short vibration event and stores the measurements so they can be reviewed afterwards.
The monitor uses a tri-axial geophone to measure ground movement in three perpendicular directions. This captures vertical, side-to-side and forward-and-back movement rather than treating the vibration as though it travels along a single line.
Together, these measurements provide a record of how the ground moved at that particular monitoring point.
Some monitoring units also include a microphone that records air overpressure. The geophone measures movement through the ground, while the microphone measures the pressure wave travelling through the air.
The two results aren’t interchangeable. A blast may sound loud or cause a window to rattle without this revealing how much ground vibration was recorded. Our guide to quarry noise management explains the distinction in more detail.
Portable monitors can be positioned at an agreed location before a blast and removed afterwards. Alternatively, a permanent monitoring station may remain installed at the same location and store or transmit each recorded event.
The most suitable arrangement depends on the quarry, its monitoring requirements and the locations being assessed. Permanent equipment isn’t required at every site.
When a vibration wave reaches a monitoring point, the ground moves very slightly backwards and forwards. Peak particle velocity, usually shortened to PPV, is the highest speed reached during that movement. It is normally measured in millimetres per second.
PPV doesn’t describe how quickly the vibration wave travels away from the blast.
It also isn’t the total distance the ground moves or a measure of earthquake magnitude. It records the movement at the monitoring point and provides a consistent figure that can be compared with the requirements applying to the quarry.
Frequency describes how many times the vibration moves through a complete cycle each second and is measured in hertz.
PPV is usually the headline figure, but frequency provides useful context because it can influence how vibration travels through the ground and how structures respond. The monitor may also save the full waveform, showing how the movement changed over the short duration of the event.
The monitoring location is chosen according to what the measurement needs to establish. This is often whether vibration at an agreed sensitive location remains within the requirements applying to the quarry.
A monitor may be positioned near a home or another vibration-sensitive property, at an agreed community monitoring point, close to the quarry boundary or near a particular structure that needs to be assessed.
The nearest property may provide the most useful location for one blast, but this can change as work moves around the quarry. The position of the blast, local geology, access and the approved monitoring scheme can all influence where measurements are taken.
Once the location has been chosen, the sensor needs to be level and firmly coupled to the ground or structure being monitored. This allows it to move with the surface and record the vibration accurately.
Loose ground, poor contact or an unsuitable surface could affect the reading. The equipment must therefore be installed in line with the monitoring procedure and the manufacturer’s instructions.
The precise procedure depends on the equipment and the quarry’s monitoring arrangements, but it generally follows three stages.
Before the blast, the monitor is installed at the selected location and checked to make sure it is ready to record. The sensor is positioned securely and details such as the monitoring point, blast location, date, time and instrument settings may be recorded.
The equipment is then set to capture the event. When the blast takes place, the monitor records the vibration waveform and movement in each of the three directions.
If the unit includes an appropriate microphone, it may also record air overpressure during the same event. This remains a separate measurement from the ground vibration reading.
Afterwards, the data is retrieved and checked. Depending on the equipment and monitoring requirements, the resulting record may include:
These records allow the result to be matched with the correct blast and compared with the requirements applying to the site.
The measurement is assessed using the method set out in the quarry’s planning condition or approved monitoring scheme. This may involve comparing the highest PPV recorded in any of the three directions with the site-specific limit.
The figure still needs to be considered in context. Its meaning can be influenced by the monitoring location, distance and direction from the blast, vibration frequency and the geology through which the waves travelled. Previous results can also help show whether the latest reading is consistent with the pattern normally recorded at that location.
Importantly, the result describes what happened at the monitoring point. It doesn’t automatically represent the vibration experienced at every property or location around the quarry.
Not necessarily. People can notice vibration at relatively low levels, while the sound of the blast, air overpressure and objects rattling inside a building can make the event feel more pronounced.
This doesn’t mean that someone is mistaken about feeling the blast. It simply means that human perception can’t establish the PPV or show whether a site-specific limit was exceeded. That requires a correctly positioned instrument and the recorded monitoring data.
An unexpected reading needs to be checked before any conclusions are drawn. Depending on the result and the site’s monitoring procedure, the operator may:
An unusual result doesn’t automatically mean that a limit has been exceeded. The checks help establish whether the reading is valid, what may have influenced it and whether further action is needed.
There isn’t one monitoring schedule followed by every quarry. The frequency and location of measurements depend on the planning conditions and monitoring arrangements applying to the individual site.
Some schemes require every blast to be monitored. Others may specify particular periods, monitoring points or a representative selection of blasts.
The arrangement may also change as extraction moves around the quarry. A location that was appropriate for one working area may not provide the most useful measurement when the blast position changes.
Quarry safety law and the planning system have different roles in the way blasting and vibration are managed.
The Quarries Regulations 1999 cover the safe organisation and supervision of blasting operations, including the appointment of a competent Explosives Supervisor.
Off-site vibration limits and monitoring requirements are commonly set through planning permission. A site-specific condition or approved scheme may establish:
Relevant British Standards and national planning guidance may also inform how vibration is measured or assessed. In England, current national minerals-planning policy requires vibration from blasting to be controlled or mitigated, while the detailed arrangements are established for the individual site.
There isn’t one PPV limit that applies to every quarry across the UK. Requirements can differ between sites and between England, Wales, Scotland and Northern Ireland.
Ground vibration monitoring turns a brief event into an objective record of what happened at a particular location. Reliable results depend on using suitable equipment, choosing an appropriate monitoring point and positioning the sensor correctly.
Those measurements can then be reviewed against the requirements applying to the quarry and used to identify anything that needs further investigation.
If you have a question about operations at one of our quarries, please contact the Armstrongs team.
A specialist ground vibration monitor, also known as a blasting seismograph or vibrograph, is normally used. It contains a tri-axial sensor and may also include a microphone for measuring air overpressure.
PPV stands for peak particle velocity. It is the highest speed at which a particle of ground moves as a vibration wave passes and is normally measured in millimetres per second.
Vibration can move the ground vertically, from side to side and forwards and backwards. Measuring all three directions provides a more complete record of the movement at that location.
They may be placed near a vibration-sensitive property, at an agreed community monitoring point, close to the quarry boundary or near a particular structure. The appropriate position depends on the blast and the site’s monitoring scheme.
No. Ground vibration travels through rock and soil, while blast noise and air overpressure travel through the atmosphere. They come from the same event but require different measurements.
Not necessarily. People can notice low levels of vibration, while air overpressure and objects rattling inside a building can make a blast feel more pronounced. Only the monitoring data can establish the recorded PPV.
It depends on the requirements applying to the quarry. Some schemes require every blast to be measured, while others specify particular monitoring periods, locations or representative blasts.
No. Limits and monitoring arrangements are generally established through site-specific planning conditions and can differ across the UK.
The equipment setup and recorded data may first be checked before the reading is compared with the site requirements. The operator can then investigate the result, notify the relevant authority where required and review future controls.
Made by Statuo